RUNNER LINK Gateway Configuring the Runner Link
9.
Click the
button.
The screen closes and only the green SYS LED continues to blink. The
other two LEDS are OFF.
10. Set the IP of your laptop back to your normal working IP.
11. Disconnect the cross cable from the Runner Link and connect the Runner
Link to the LAN or WAN.
Setting the Board to the Factory Default IP Address
1. Using Figure 3 on page 6 as a guide, short the Reset jumper pins using
the jumper installed on one of the pins.
2. Press the CONFIG button.
The board is now reset to the factory defaults.
NOTE
You can also reset the Runner Link by turning on power to the
board when the pins are shorted using the jumper. You can then
remove the jumper and plug it onto one of the pins for safe
keeping.
Setting the RUNNER panel with Account code and activate the dialer
The next steps are very essential in order to enable delivery of RUNNER panel
events to the monitoring center station:
1. Enter to the RUNNER panel Installer mode
2. Define the account number: P62EXXXXE (XXXX=Account Number)
3. Activate/or verify activation of the dialer : P175E1E
12